Sage Modeling and Simulation Library

TemperatureControllerMode Enumeration

This is the operating mode for the Temperature Controller. The temperature controller will either maintain a constant driving temperature in the cooling or heating medium (constant_T mode), it will maintain a constant delta T across the boundary between the cooling or heating medium and the mixture (as in the constant_DeltaT mode), or it will manipulate the deltaT to ensure a constant temperature ramp rate in the mixture.

Namespace:  Highpoint.Sage.Materials.Thermodynamics
Assembly:  Sage4 (in Sage4.dll)

Syntax


public enum TemperatureControllerMode

Members


Member nameDescription
ConstantT Maintains a constant driving temperature in the cooling or heating medium (constant_T mode)
ConstantDeltaT Maintains a constant delta T across the boundary between the cooling or heating medium and the mixture.
Constant_RampRate Maintains a constant temperature ramp-rate in the mixture.